professional medical

Series of Container Leakage Test

  • MF-A Blister Pack Leak Tester

    MF-A Blister Pack Leak Tester

    The tester is applied in the pharmaceutical and food industries for checking air-tightness of packages (i.e. blisters, injection vials, etc. ) under negative pressure.
    Negative pressure test: -100kPa~-50kPa; resolution: -0.1kPa;
    Error: within ±2.5% of reading
    Duration: 5s~99.9s; error: within ±1s

  • NM-0613 Leak Tester for Empty Plastics Container

    NM-0613 Leak Tester for Empty Plastics Container

    The tester is designed according to GB 14232.1-2004 (idt ISO 3826-1:2003 Plastics collapsible containers for human blood and blood components – Part 1: Conventional containers) and YY0613-2007 “Blood components separation sets for single use, centrifuge bag type”. It applies an internal air pressure to the plastics container (i.e blood bags, infusion bags, tubes, etc.) for air leakage test. In use of absolute pressure transmitter matched with secondary meter, it has advantages of constant pressure, high precision, clear display and easy handling.
    Positive pressure output: settable from 15kPa to 50kPa above local atmospheric pressure; with LED digital display: error: within ±2% of reading.

  • RQ868-A Medical Material Heat Seal Strength Tester

    RQ868-A Medical Material Heat Seal Strength Tester

    The tester is designed and manufactured according to EN868-5 “Packaging materials and systems for medical devices which are to be sterilized—Part 5: Heat and self-sealable pouches and reels of paper and plastic film construction—Requirements and test methods”. It is used for determining the strength of the heat seal joint for pouches and reel material.
    Itconsists of PLC, touch screen, transmission unit, step motor, sensor, jaw, printer, etc. Operators can choose the needed option, set each parameter, and start the test on the touch screen. The tester can record the maximum and average heat seal strength and from the curve of the heat seal strentgth of each test piece in N per 15mm width. The built-in printer can print the test report.
    Peeling force: 0~50N; resolution: 0.01N; error: within ±2% of reading
    Separation rate: 200mm/min, 250 mm/min and 300mm/min; error: within ±5% of reading

  • WM-0613 Plastic Container Burst and Seal Strength Tester

    WM-0613 Plastic Container Burst and Seal Strength Tester

    The tester is designed according to GB 14232.1-2004 (idt ISO 3826-1:2003 Plastics collapsible containers for human blood and blood components – Part 1: Conventional containers) and YY0613-2007 “Blood components separation sets for single use, centrifuge bag type”. It uses transmission unit to squeeze the plastics container (i.e. blood bags, infusion bags, etc. ) between two plates for lquid leakage test and digitally displays the value of pressure, so it has advantages of constant pressure, high precision, clear display and easy handling.
    Range of negative pressure: settable from 15kPa to 50kPa above local atmospheric pressure; with LED digital display; error: within±2% of reading.